Technical Data
Nominal capacityDesign data- Pressure: - 1 to +6 bar
- Temperature : -25 to +200°C
Design and calculation codes- VSR/AD-Merkblatter/ASME VIII div.1/CE stamp
- PED 97/23/EC module cat. IV
Construction toleranceConstruction- BE : one piece construction
Jacket design- As standard type B1 acc. to DIN 28151
- On request other types acc. to DIN 28151
Design of half-pipe coil- Design of half-pipe coil
- The half-pipe coil is supplied as an alternative to the jacket.
- Shape of the fluid flow section : half-pipe (DIN 28128)
- Zones : one or more to be agreed
- Single or double circuit : to be agreed
Nozzles- Flanges to DIN 2501 PN 10
- All glass-lined nozzle are complete with loose backing split flanges acc. to DIN 28150
- Other flange standards (ANSI) on request
Gaskets- PTFE envelope type with stainless steel insert for all glass-lined connections
Agitator system BE:- Removable turbine agitator with presslock
- Coupling system
- Standard design : three blade 45 degree
- Pitched-blade turbine combined with beaver tail
- Baffle(s) acc. to DIN 28146
- Other designs available on request : Retreat-blade impellers acc. to DIN 28157 (two piece construction), multiple turbine agitators, wide blade turbine, etc..
Drive unit- Asynchronous three-phase electric motor, EEx-d certified
- Speed reducer with ground profile gears
- Connection between motor and reduction gear : direct monted
- Pedestal acc. to DIN 28162 T1 (with drive flange acc. to DIN 28137)
Atex conformityOur standard : external + internal = Group II , Category 2 , G (zone 1) D (zone 21)
Shaft seal- Acc. to DIN 28138 T2 and T3
- Double
mechanical seal assembly of cartridge design for quick replacement,
side dismantling without removal of gear with thermometer and pressure
gauge
- Pressurising and lubrication unit with thermosyphon circulation complete with hand-pump for topping up
Supports- Legs - Side brackets - Support rings acc. to DIN 28145 T4
- Other designs supplied on request
Glass-Lining- Vessel G2208 Blue, White or Light-Blue
- Available also other types of glass to suit specific requirements.
More specific data can be obtained from our laboratories
Test and inspection of the glass-lining to DIN 28063- Visual
inspection - Thickness control of the coating
- Statiflux (electrified
particle test)
- Spark test to ISO 2746 - For vessel and accessories, at
20.000V immediately after glass-lining. For vessel and accessories, at
12.000V prior to shipment
The supply includes- Glass-lined
protection ring for the manhole
- Spring-assisted lifting device to
open the manway cover
- Sight glass
- Light glass.