Full seal-welded sheathing/insulationFiber/Rockwool insulation
Foamglas insulation available
304 or 316 stainless steel cladding:
- External satin finish (180 grit)
Manway Cover - 304 stainless steel
- Glass-lined 304 stainless steel
- Other MOC and glass-lined MOC available.
Easy Opening PortQuick opening hinged 4" sight glass installed on the manway that closes using 4 hand-tightened bolts.
Lump breakersFor future installation of two lump breakers:
- Install special support arm for electrical passage
- Electrical power rotating distributor
- 2 additional shell nozzles.
Primary installation
- Unit supplied with one multiblade lump breaker
- 4hp (3kW) motor with speed reduction stage via a gear box
- Mechanical wet seals and seal pot with internal cooling coil for barrier fluid.
- Wetted parts in Hastelloy C22
Through-the-Wall Design in Stainless Steel (to separate clean room from machine operating side components)
Discharge Valve An
8" manual wafer butterfly valve supplied as a discharge nozzle. The
body is PTFE lined cast iron, the disc in Hastelloy C. The outlet
connection is tri-clamp style 8"/DN200 in 316L.
Sampling ValveSupplied with an Alloy C22 dip pipe, PFA-lined cast iron ball valve and a GL45 glass bottle with 100ml volume.
Temperature TransmitterA 2xPt100 and a 4-20mA Hart transmitter is supplied for internal vessel temperature detection.
Pressure TransmitterAn internal pressure transmitter with Hart communication is supplied.
Personnel SafetyFor
personnel safety a key interlock system has been implemented. The
operator can access the unit (rounding area, manway, sight glass) only
by using the key box system. Each key can be released only if all
movements are stopped and power interrupted. This system includes an
electric power cut off switch that must be wired between the power
source and motors.
Docking System for Automatic Filling & DischargeFor
automatic filling and discharge operations, we offer a split valve
based system.. To charge, a telescopic system with 75mm stroke connects
the active (alpha) part of a split valve to the passive (beta) part
mounted onto the dryer. When the two parts are connected, the valve can
be opened like a butterfly valve to charge the dryer. This system must
be operated at ambient pressure and at max 80°C. System is operated
with a pneumatic butterfly valve between the passive part and the
internal of the dryer. The docking system is in stainless steel 316L.
The same assembly is used for discharge. The two active